Fault Code | Possible Cause |
E01 | Ignition failure – the boiler has attempted to light 5 times and not succeeded – check the gas supply is on |
E02 | False flame – possibly a problem with the power supply |
E03 | Boiler overheat – check that any valves to the heating circuit have not been shut down, no air in the system and that the water pressure is correct |
E05 | Fan failure – boiler cannot detect fan rotation – check fan operation and both connectors onto fan |
E07 | Flue overheat – check combustion and flue temperature vs. return temperature – the flue temperature should be no more than 10C above return temperature. Possible heat exchanger fault. |
E08 | Flame circuit error – possible control box fault |
E09 | Valve drive error – possible gas valve or control box fault |
E10 | Control box errors – possible faulty control box |
E11 | The automatic test for calibration of flow and return sensors has failed – check both flow and return sensors are located on the correct pipes and are producing the correct readings |
E12 to E22 | Control box errors – possible faulty control box |
E23 | Water filling error – check water pressure sensor |
E24 | Water pressure lost 4 times in 24 hours – possible leak, check system and boiler |
E25 | Control box errors – possible faulty control box |
E26 | Flame drop out – check for obstruction of the flue and/or air terminals, blockage/freezing of the drain pipe or a low gas supply (LPG). |
E30 | Flow sensor short circuit – check connections to flow sensor |
E31 | Flow sensor open circuit – check connections to flow sensor are in place |
E32 | DHW sensor short circuit – check connections to domestic hot water (DHW) sensor |
E33 | Domestic hot water (DHW) sensor short circuit – check connections to DHW sensor are in place |
E34 | Mains supply voltage < 180V – may be a problem with your power supply |
E35 | Mains supply frequency incorrect – may be a problem with the power supply |
E37 | Water pressure error – increase the system water pressure |
E38 | Reset key fault – replace fascia PCB |
E40 | Water pressure too high |
E41 | Communication error between fascia and control box – check cables |
E43 | Return sensor short circuit – check connections to return sensor |
E44 | Return sensor open circuit – check connections to return sensor are in place |
E45 | Flue sensor short circuit – check connections to flue sensor |
E46 | Communication error between fascia and control box – check cables |
E99 | Flue sensor short circuit – check connections to flue sensor are in place |