Worcester Bosch Oil Boiler Error Codes 2022

Worcester Bosch Oil Boiler Error Codes

What you find on this page:

The Worcester Bosch range of Combi, Regular and System oil boilers show either an error code on the digital display or have a sequence of flashing lights to help identify the cause of any faults.

Use the table below to find out what the various error codes and flashing light sequences on Worcester Bosch oil boilers all mean.

Lockout – false flame signal

Fault DescriptioneSystem Behaviour
Red steady onLockout – no flame and safety time
Red 0.5 seconds on, red 0.5 seconds off
Red 0.2 seconds on, red 0.2 seconds offLockout – maximum number of flame loss relights
Red 2.5 seconds on, orange 0.5 seconds onLockout – fan motor failure
Red 2.5 seconds on, green 0.5 seconds onLockout – oil valve circuit driver failure
Orange 0.5 seconds on, green 0.5 seconds onLockout – EEPROM failure
Red 0.5 seconds, on red seconds offMax pre-heat time exceeded
Green 0.5 seconds on, green 2.5 seconds offPre-heating time error
Green 0.5 seconds on, red 0.5 seconds onExtraneous light – lockout after 25 seconds
Orange steady onPre-purge the burner remains in prep-purge
After ignition burner remains in operation
When anomalies disappear the burner re-starts
Orange 0.2 seconds on, green 0.2 seconds onControl box internal error
Green 0.2 seconds on, green 0.2 seconds onRemote reset button is activated for more than 60 seconds – when anomaly appears the burner does not stop
1Control box is supplier with heat demand
2The pre-heater is fitted or if no pre-heater is fitted is the link fitted
3AGreen 0.5 seconds on / red 0.5 seconds on before lockout
3BFan motor or oil pump is seized
3C230 volts to motor across blue and black motor wired
3DApproximately 35 across blue and black motor wires
4AMotor gives 50 volts a.c across black and white wires
5ABurner fires when the photocell is covered
5BPhotocell voltage 3.8> in the dark and approximately 0v in the light
6APump pressure more than 6 bar
6BCheck oil supply to the pump
6CDrive coupling broken
7AAre ignition leads and electrodes ok and set correctly
8ADoes burner light or green 0.5 seconds on / red 0.5 seconds before lockout
8BContaminated fuel filter
8CCoil lead okay
8DSolenoid coil resistance
8EAfter 15 seconds from motor start 25 to 30 volts
10AIs the nozzle atomising the fuel
10BNeeds new nozzle
10CCheck oil pipe from pump to nozzle holder
11AFlame goes out then relights
11BBoiler or flue blocked
11CIbalance flue and snorkel test
11DBalanced flues can recirculates gases causing recycling
11EPhotocell voltage 3.8 in the dark and approximately 0v in light

Worcester Bosch Error Code EA 229 or D5

If you’re seeing the error code EA 229 or D5 on your Worcester Bosch boiler, this means that the condensate pipe is frozen. This happens due to the condensate pipe running outside, however this is an issue that you could fix yourself if you feel confident enough.