Ravenheat Boiler Error Codes
| Fault Code | System Behaviour |
| F73 | Heating circuit pressure sensor fault |
| F74 | Heating circuit pressure sensor fault |
| F76 | Thermal fuse fault |
| F77 | Fault in gas valve motor |
| F83 | No water in the installation – the temperature does not increase when the burner is lit |
| F84 | Permanent temperature difference betweenF flow and return heating sensors |
| F85 | Flow and return heating sensors fault |
| F86 | Underfloor heating contact fault |
| ERR | User interface fault |
| 04 | Domestic hot water (DHW) sensor faulty |
Ravenheat CSI 120 Boiler Error Codes
| Fault Code | System Behaviour |
| 17 | Possible issue with fan voltage |
| 01 | Boiler failed to ignite – problem with gas valve operation, fan failing to start, ignition control board and cables |
| 28 | Failed low water – pressure switch or pump, possible issue with pump, incorrect system pressure or the low water switch pressure needs replacing |
| 12 | Failed heating sensor – issue with heating sensor and could need replacing |
| 04 | Failed overheat – the overheat thermostat needs checking |
| 30 | Failed flue temperature – check operating system |
| 31 | Failed flue temperature – the flue sensor needs checking or replacing |
| 02 | Failed temperature – try resetting the boiler |
Ravenheat CS 80/90, WH System, WH 80/90 Boiler Error Codes
| Fault Code | System Behaviour |
| E02 | Problem with the pump circulation |
| E03 | Flow sensor damaged |
| E04 | Domestic hot water (DHW) sensor damaged |
| E05 | Problem with fan – possibly no signal |
| E06 | Central heating (CH) sensor is overheating |
| E08 | Low water pressure |
| E09 | Overheat sensor overheating |
| E10 | High water pressure |
| E13 | Software error |
| E21 | Central heating (CH) return sensor overheating |
| E22 | Flue sensor overheating |
| E23 | Flue sensor damaged |
| E24 | Central heating return sensor error – possibly damaged |
| E25 | Main heat exchanger frozen |
| E29 | Domestic hot water (DHW) sensor overheating error |
| E31 | OpenTherm communication error |
| E41 | Different flow/return temperatures |
| E42 | Different temperature error |
| E43 | Different temperature error |
| E44 | Different temperature error |
| E46 | Water pressure sensor error – could be open or short |
Ravenheat HE 80/90 HE 25-30s, HE 80-98s, HE 8-98s or HE 25-30s compact
Different temperature error
| Fault Code | System Behaviour |
| 02E | Problem with the pump circulation |
| 03E | Flow sensor damaged |
| 04E | Domestic hot water (DHW) sensor damaged |
| 05E | Problem with fan, possibly no signal |
| 06E | Central heating sensor is overheating |
| 08E | Low water pressure |
| 09E | Overheat sensor overheating |
| 10E | High water pressure error |
| 13E | Software error |
| 21E | Central heating return sensor overheating |
| 22E | Flue sensor overheating |
| 23E | Flue sensor damaged |
| 24E | Central heating return sensor error, possibly damaged |
| 25E | Main heat exchanger frozen |
| 29E | D.H/W sensor overheating error |
| 31E | OpenTherm (OT) communication error |
| 41E | Different temperature between flow and return |
| 42E | Different temperature error |
| 43E | |
| 44E | Different temperature error |
| 46E | Water pressure sensor error, could be open or short |